Rolling Stock Cables
EN 50264 EN 50306 EN 50382 Databus Cables NF F 63-826 NF F 63-808 NF F 63-827 RSE/STD/024 PART 6

FIREROL Thin Wall Multipair Overall Screen Cables with Standrad Wall Sheath 300/500 V

EN 50306-4 (FRL-TW-05MP-SW-OS)

FIREROL FRL-TW-05MP-ESW-IOS

                                   A.Conductor      B.Insulation       C.Overall Screen         D.Sheath

Application

-Used as signal and control cable for protected installations inside and outside of rail and transport vehicles,

where space and weight are an important factor.

-Used in cable harnesses, switchboards and control panels, driver desks etc.

Construction

Conductor

Tinned annealed copper wires as defined in EN 50306-2

Insulation

LSZH special compound

Overall screen

Tinned annealed copper wires

Pair Identification

Pairs numbered according to EN 50306-4

Outer sheath

LSZH special compound (S2. EM 101 - EM 104)

Electrical & Mechanical Properties

Nominal Voltage:300/500 V

Maximum Conductor Temperature:+90/+105 deg (fixed installation)

Minimum Permissible Ambient Temperature:-25/-40 deg (fixed installation)

Bending Radius:10 x Overall Diameter

Chemical & Environmental Properties

EN 60684-2:No fluorine

EN 50305; EN 60811-2-1:Resistance to mineral oil & fuel oil, acid & alkali

EN 50305:Resistance to ozone

Fire Performance for rolling stock application

EN 50306-2:Hazard levels HL1, HL2/HL3

DIN 5510-2:Protection level 1/2/3/4

BS 6853:Interior use 1a, 1b, II; Exterior use 1a, 1b, II

NF F 16-101:FO

EN45545-2:R15 Interior/ R16 Exterior HL1, HL2, HL3

Fire Performance in general

EN 50265-2-1; IEC 60332-1-2; NF C 32-070 2.1 (C2) Vertical flame propogation for a single insulated wire or cable
EN 50266-2-4 + EN 50305; IEC 60332-3-24;
NF C 32-070 2.2 (C1); VDE 0472 Teil 804
Vertical flame spread of vertically mounted bunched wires or cables
EN 50268-2; IEC 61034-2; NF C 32-073 ;
NF C 20-902; NF F 16 101; VDE 0472 Teil 816
Low Smoke Emission
EN 50267-2-1; IEC 60754-1; NF C 32-074;NF C 20-454; VDE 0472 Teil 815 Halogen Free
EN 50267-2-2/3; IEC 60754-2; NF C 32-074;NF C 20-453; VDE 0472 Teil 813 Low Corrosivity (Acidity & Conductivity)
EN 50305; NFX 70-100; NFF 63808; TM1-04; BS6853 Low Toxicity
NFF 16101; NFF 63808; BS6853 Smoke index
EN45545-2 Requirement for fire behavior of materials & components
R15/R16

FRL-TW-05MP-ESW-OS 300/500 V

Number of Pairs and Nominal Cross Section

Min. Thickness of Sheath at
any Point

Overall Diameter

 

Weight

Min.

Max.

N x n x mm2

mm

mm

mm

kg/km

2 x 2 x 0.5

0.56

6.6

7.9

61

3 x 2 x 0.5

0.56

7.0

8.1

78

4 x 2 x 0.5

0.56

7.7

8.7

96

7 x 2 x 0.5

0.56

9.0

10.6

146

 

2 x 2 x 0.75

0.56

7.1

9.0

80

3 x 2 x 0.75

0.56

7.7

9.2

103

4 x 2 x 0.75

0.56

9.0

10.0

128

7 x 2 x 0.75

0.56

10.8

11.8

200

 

2 x 2 x 1.0

0.56

7.8

9.5

95

3 x 2 x 1.0

0.56

8.3

9.7

125

4 x 2 x 1.0

0.56

9.1

10.3

156

7 x 2 x 1.0

0.56

11.0

12.4

247

 

2 x 2 x 1.5

0.56

9.8

11.2

126

3 x 2 x 1.5

0.56

10.4

11.4

168

4 x 2 x 1.5

0.56

11.6

12.6

212

7 x 2 x 1.5

0.56

14.0

15.3

340

Note: The parameters listed above are nominal values as per cable standards. Actual values may vary due to material and manufacturing process variations. For precise specifications or customized requirements, please contact us for further information